Temperature impact:
Temperature impact of a temperature at room temperature 2 negative impact to the impact of cycle time means Remarks
-20 ℃ (5 min) 2min 90 ℃ (5 min) 2-gas impact
-30 ℃ (5 min) 5min 105 ℃ (5 min) 10-gas impact
-30 ℃ (30 min) 105 ℃ (30 min) 10-gas impact
88 ℃ (20 min) -44 ℃ (20 min) 10-gas impact
100 ℃ (30 min) -40 ℃ (30 min) 30-gas impact
100 ℃ (15 min) -40 ℃ (15 min) 5min 300 gas-impact high-brightness LED
100 ℃ (5 min) -10 ℃ (5 min) 300 liquid-impact high-brightness LED
LED high temperature and humidity:
Temperature and humidity conditions of the time Note:
40 ℃ / 95% RH 96小时
60 ℃ / 85% RH 500小时life test
60 ℃ / 90% RH 1000小时life test
60 ℃ / 95% RH 500小时life test
85 ℃ / 85% RH 50小时
85 ℃ / 85% RH 1000小时life test
Life Test at room temperature:
27 ℃ 1000小时increase for current lit
High-temperature life test:
85 ℃ 1000小时increase for current lit
100 ℃ 1000小时increase for current lit
Low-temperature life test:
-40 ℃ 1000小时increase for current lit
-45 ℃ 1000小时increase for current lit
James-test:
Test conditions: Note:
LED's legs (from the bottom of colloidal 1.6 mm) ingress 260 ℃-five second slot
LED's legs (from the bottom of colloidal 1.6 mm) ingress 260 +5 ℃-tank six seconds
LED's legs (from the bottom of colloidal 1.6 mm) ingress 300 ℃-tank three seconds
Reflow furnace test:
240 ℃ 10秒
Environmental testing (260 ℃ ± 5 ℃ under TTW solder temperature for 10 seconds)
Test name reference standard reference JIS C 7021 test conditions content
Test temperature / time reverted to the presence of a few cycle (H)
Temperature impact of MIL-STD-883 method 1010 -55 ℃ ← → 100 ℃, 15分钟presence of air - air storage. Five minutes 50/100/1000
Temperature impact of MIL-STD-883 method 1010 -40 ℃ ← → 100 ℃, 15分钟presence of air - air storage. Five minutes 5/65/100/200
Temperature impact of MIL-STD-883 method 1010 -40 ℃ ← → 100 ℃, 15分钟presence of <10 seconds conversion, the air - air storage. 15 minutes 5/50/100
Motor cycle power temperature norms -40 ℃ ← → 85 ℃, 18分钟presence, 42 minutes conversion, and current, five minutes on / off 100/500
Motor cycle power temperature norms -40 ℃ ← → 85 ℃, 15分钟shutdown / conversion, and current, five minutes on / off, the presence of 500 h, 100h 100
Power temperature cycle -40 ℃ ← → 105 ℃, 15分钟shutdown / conversion, and current, five minutes on / off, 168 h
Temperature cycle of 85 ℃ / 85% RH, and current, 500 H/1000H
Temperature cycle of 60 ℃ / 95% RH, and current, 24h/168h/1000h
JIS C 7021 high-temperature storage methods B-10 110 ℃, 500 H/1000H
Environmental testing (240 ℃ ± 5 ℃ under TTW solder temperature for 10 seconds)
Test name reference standard reference JIS C 7021 test conditions content
Test temperature / time reverted to the presence of a few cycle (H)
Motor cycle regulating temperature -40 ℃ ← → 100 ℃, 15分钟the presence of five minutes 5/50/100/1000
Temperature cycle of 60 ℃ / 95% RH, plus current 50/1000
Humidity reverse bias MIL-STD-883 method 1010 60 ℃ / 95% RH, 5V RB 50/1000